Work

Proceedings, 11th Patras Workshop on Axions, WIMPs and WISPs (Axion-WIMP 2015)

Year: 2015
Type: conference-paper
Abstract: The KWISP opto-mechanical force sensor has been built and calibrated in the INFN Trieste optics laboratory and is now under off-beam commissioning at CAST. It is designed to detect the pressure exerted by a flux of solar Chameleons on a thin (100 nm) Si$_3$N$_4$ micromembrane thanks to their direct coupling to matter. A thermally-limited force sensitivity of $1.5 \cdot 10^{-14}~\mbox{N}/\sqrt{\mbox{Hz}}$, corresponding to $7.5 \cdot 10^{-16}~\mbox{m}/\sqrt{\mbox{Hz}}$ in terms of displacement, has been obtained. An originally developed prototype chameleon chopper has been used in combination with the KWISP force sensor to conduct preliminary searches for solar chamaleons.
Language: English
Open Access status: green
OpenAlex ID: W7014719953
FWCI: 2.65
Cites: 9
Cited by: 4
Related to: 10