A reply

Year: 1998
Type: article
Abstract: It is a challenge for the designers of patient monitors to counteract problems which can arise as a result of different users using the same monitor. Hewlett-Packard is working continuously to enhance monitoring capabilities in this respect. The particular problem described occurred as a result of the rare situation where a user, apparently not completely familiar with the device, made a change to the configuration without due regard for the consequences. The component monitoring system (CMS) functioned according to specification. It is clear from the description that the arterial blood pressure numeric had been disabled by a previous user. The facility to switch off individual numerics is employed for example when the user wishes to remove extraneous information from the screen. (The reason why in this case the ABP numeric was switched off is not given.) Naturally the CMS is delivered from the factory with all parameter numerics switched on. The CMS can interpret a vast amount of information from measurement modules, procedures and external devices and is designed to provide as much useful information as possible to the user. It is the user's decision which information needs to be displayed and which not. If more parameters are being measured than can be displayed on the screen, then compromises have to be made and the CMS assists in this respect with some automatic fall-backs. A check is made to determine whether the user has switched off any numerics. If so, then a parameter which would not otherwise be displayed is shown on the CMS in the channel where the switched-off numeric would have been displayed. Individual numerics on the CMS can be switched off in normal monitoring mode. When this occurs, a status message ‘Not all numerics displayed’ is shown. The numerics will remain switched off for as long as the CMS is powered on. If the user wants to permanently switch off a numeric (even after the CMS has been powered off and on again), the user is prompted to press ‘Confirm’ after switching off a numeric. The capability to switch off numerics was introduced as a result of requests from customers. Our customers tell us that both the wave and the numeric for a parameter such as arterial blood pressure is required for proper monitoring and to visualise alarm situations. For this reason, switching a numeric off on a CMS means that both the wave and numeric for that parameter can be replaced in heavy-use situations.
Source: Anaesthesia
Author: G. Wylie
Language: Kazakh
Subfield: Surgery
Field: Medicine
Open Access status: bronze
OpenAlex ID: W2333658918
FWCI:
Cites: 4
Cited by: 1
Related to: 10