Experimental Measurement of Tool-Chip Interface Temperature With Pyrometer in Turning
Year: 2011
Type: article
Abstract: In this study, tool-chip interface temperature occurred during machining of AISI 1040 steel with uncoated cementedcarbide inserts were measured. Machining experiments were performed on a CNC lathe under dry conditions. In the experiments,five different cutting speeds (75-125-175-225-275 m/min), three different feed rate (0,1-0,2-0,3 mm/rev) and two different depthof cut (1-2 mm) were used. During cutting process, temperature values measured at the closest point to tool-chip interface wererecorded to a personal computer using a pyrometer, fiber optic cables and other circuit elements. According to experimentalresults, it was determined that temperature generated on cutting zone increased with increases in depth of cut and feed rate.Additionally, tool-chip interface temperature increased with increasing cutting speed, but the tendency of increase in thetemperature slightly decreased after cutting speed of 125 m/min
Source: Journal of Polytechnic
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W1584914085