Abstract: The effect of coaxially placed entry region twisted tape as turbulence promoter on momentum transfer rates in forced convection flow of electrolyte were studied in an circular conduit. The friction correlation was based on the law of wall similarity. The study covered a wide range of variables such as the flow rate of electrolyte, geometric parameters such as pitch of the tape (TP) which varied from 0.02 m to 0.12 m, length of the tape (TL) which varied from 0.14 m to 0.22 m and width of the tape (TW) which varied from 0.01 m to 0.03 m. The results revealed that the friction factor increased with increase in TL and TW and decreased with increase in TP. Momentum transfer rates were analyzed with momentum transfer roughness function in place of friction factor (f) and roughness Reynolds number ( Re ) in place of Reynolds number (Re). The following correlation was reported out of the study: R(h ) = 18.581(Re )–0.109 ( 1)0.374 ( 2)0.001 ( 3)0.019. The correlation which was developed can be extended to a wider range of variables by virtue of law of wall similarity.