Abstract: In tissue harmonic imaging (THI) the images are formed using the second harmonic \ncomponent that is generated nonlinearly when ultrasound propagates inside \nthe body. THI improves image resolution by reducing effects of phase distortion \nand reverberation in the body wall layer. A statistical investigation was \nperformed to quantify improvement achieved with THI in the presence of tissue \ninhomogeneity. The investigation was both theoretical and experimental. In the \ntheoretical model, a thin random phase screen located just in front of the source \napproximates the effect of inhomogeneity in the body wall layer. The phase \nvariations across the screen are characterized statistically by zero mean, small \nvariance, and Gaussian spatial correlation function. An analytical solution was \nderived for the expected value of the intensity of the second harmonic for a source \nthat radiates a focused Gaussian beam. Contributions due to the coherent and \nscattered field components appear as separate terms in the solution. Validity \nof the statistical solution was established by comparison with ensemble averages \nof direct numerical simulations. Evolution of the beam profile and variation in \nenergy content of the scattered second harmonic as a function of phase screen \nstatistics are discussed. In comparison with the scattered field at the source \nfrequency, the scattered field at the second-harmonic frequency is shown to be \nmore localized about the beam axis. The results demonstrate clearly and quantitatively \nhow distortions due to phase aberrations near the source are reduced \nby THI. Numerical simulations were also performed for beams radiated from a \nfocused circular source with uniform amplitude. These results exhibit similar \nbehavior. Dependence of results from the theoretical model on the distance between \nthe source and phase screen was investigated. A transformation based on \ngeometrical acoustics was obtained that approximates the mean scattered field \ndue to a phase screen at a given distance away from the source using the solution \nobtained when the phase screen is in the source plane. Use of multiple \nphase screens to approximate thick inhomogeneous layers was also investigated. \nExperiments performed with a focused circular source and phase screens created \nwith randomly indented plastic plates confirm the general theoretical approach.
Author: Xiang Yan
Institution: The University of Texas at Austin
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
Funder: Office of Naval Research
OpenAlex ID: W2340956971