Work

Hemoglobin içeriğine dayalı transfüzyon ile standart eritrosit süspansiyonu transfüzyon etkinliğinin karşılaştırılması

Year: 2011
Type: article
Study design: Clinical Trial
Abstract: Eritrosit suspansiyonu (ES) unitelerinin hacimleri standart kriterlerle belirlenmisse de hemoglobin (Hb) icerikleri farklidir. Halen klinik rutin transfuzyon uygulamalari, eritrosit suspansiyonlarinin unite sayisina dayanmaktadir. Simdiye kadar Hb icerigine ve unite sayisina dayali transfuzyon uygulamalari arasinda karsilastirmali calisma yapilmamistir. Biz bu calisma ile iki yontemin etkinliklerini karsilastirmayi amacladik.89 hasta calismada yer aldi (55 erkek; 34 kadin). Ortanca yas 46 (19-75) ve tanilar; 44 Akut losemi, 17 lenfoproliferatif hastalik, 11 plazma hucre hastaligi, 15 kemik iligi yetmezligi, 1 orak hucreli anemi ve 1 solid tumor; olarak belirlendi. Uygulanan 178 transfuzyon epizodunun; 92' si calisma, 86' si kontrol koluna randomize edildi. 51 hasta 1, 38 hasta ?2 epizotta degerlendirildi (ortanca 3; 1-7). Hesaplamalar kan bankalarimizda kullanilan, Hemosoft Isletim Sistemi'yle yapildi. ES unitesi Hb icerigi; donor Hb'i dogrultusunda hesaplandi. Calisma kolunda alici; boy, guncel kilo, guncel ve hedef Hb verileri ile gerekli Hb miktari hesaplandi ve stokta yeterli Hb iceriginde ES bulunabilirse (basarili), unite sayisinin azaltilmasi hedeflendi. Uygun unite bulunamayanlarda (basarisiz) ve kontrol kolunda istenen sayida ES unitesi gonderildi. Transfuzyon sonrasi 2. saatte Hb kontrolu yapildi. Calisma ve kontrol kolunda hasta ozellikleri benzerdi. Calisma kolunda 92 epizodun 84' unde 2, 8'inde 3 unite ES istemi yapildi. 38 epizotta uygun unite bulundu (%41,3; 38/92). 30'unda, 2'de 1 unite ve 8'inde, 3'de 1 unite ES azaltildi (% 19,8; 38/192). Uygun Hb iceriginde unite bulma basarisi; dusuk kilolu, kisa boylu hastalarda ve ES stok sayisi fazla oldugunda; daha yuksek bulundu. Kontrol kolunda 86 epizotta da 2 unite istendi ve gonderildi. Hedeflenen Hb degerine ulasma oranlari; calisma ve kontrol kolunda (p=0,1), basarili ve basarisiz gruplarda (p=0,3), kontrol kolu ve basarisiz grupta (p= 0,4); istatistiksel olarak benzer bulundu. Unite Hb icerigi ve hedef Hb'e ulasma iliskisinin, anlamli oldugu gosterildi (p=0,01). Raf omru ve hedef Hb'e ulasma iliskisi anlamsizdi (p=0,7).Sonuc olarak; Hb icerigine dayali ve unite sayisina dayali ES transfuzyonlarinin, etkinliklerinin benzer oldugunu gosterdik. Hb icerigine dayali transfuzyon ile unite sayisinda tasarruf ettik. Uygun Hb iceriginde ES unitesi bulma basarisinin; stok sayisi ile dogru, vucut agirligi ve boy ile ters orantili oldugunu saptadik. AbstractAlthough the volume of the red blood cell (RBC) units has been identified according to the standards, the hemoglobin (Hb) content of them are all different. In practice, the RBC transfusions are based on the number of units. No study has yet been carried out to compare an Hb content-based RBC transfusion with a unit-based one. In this study, we aimed to compare the efficiencies of these two different RBC transfusion methods.89 patients were enrolled for the study. The median age was 46 (range, 19-75). Male-to-female ratio was 55:34 and patients? diganoses were; 44 acute leukemia, 17 lymphoproliferative disorder, 11 plasma cell disorders, 15 bone marrow defects, 1 sickle cell disease and 1 solid tumor. 92 of the 178 transfusion episodes were randomly allocated to the study group and 86 of them to the control group. The calculations were done by Hemosoft Blood Banking Management & Information System, an in-house software used within the Blood Bank of our hospital. The Hb level of the units was calculated with respect to the donors? Hb concentrations. Within the study group, the required Hb amount was calculated based on the patients? height, actual body weight (ABW) and their actual and targeted Hb. The Hb levels of the RBC units within the inventory were checked and if an available RBC unit with the required Hb amount was found, used in order to reduce the number of RBC units transfused. The number of units as ordered was used in cases where there were no available matching RBC unit and within the control group. Posttransfusion Hb was checked 2 hours after transfusion. Characteristics of the patients, within the study group and the control group, were similar. 51 patients had only 1 transfusion episode and 38 patients had 2 or more (median 3; range 1-7)2 units were ordered for 84 of the 92 episodes within the study group and 3 units were ordered for 8 of them. A suitable matching unit was found for 38 of the episodes. (41.3%; 38/92). Two-unit orders were reduced to one within 30 episodes and three unit orders were reduced to two within 8 episodes (19,8%; 38/192 ). The possibility of finding a suitable unit was higher within low weight-short patients and within a bigger size of inventory. The ratio of achieving the target Hb within the study group and the control group (p=0,1), within the matched and unmatched groups (p=0,3) and within the control group and the unmatched group (p=0,4) were similar. The relation between the Hb content of the RBC unit and the rate of achieving the target Hb was found to be significant (p=0,01). The relation between the shelf life of the RBC units and the rate of achieving the target Hb was found to be insignificant (p=0,7).As a result; we demonstrated that the efficiencies of Hb content-based and unit- based RBC transfusion policies were similar. Less number of RBC units were used by Hb-content based transfusion policy. We also demonstrated that the possibility of finding a suitable Hb content match was directly proportinal to the size of the inventory and inversely proportional to the weight and height of the patient.
Author: Erden Atilla
Language: Turkish
Subfield: Hematology
Field: Medicine
Open Access status: diamond
OpenAlex ID: W2346327293
FWCI:
Cites:
Cited by:
Related to: 10