Characterization of Sandia Capacitive Comb-finger MEMS Accelerometers
Year: 2015
Type: article
Abstract: This paper discusses various methods for testing the performance of MEMS capacitive comb-finger accelerometers manufactured by Sandia National Laboratories. The use of Capacitive MEMS devices requires complex circuits for measurement of capacitance and the Sandia MEMS accelerometer’s capacitance changes in a very small femto-farad (fF) range. The performance of accelerometer is tested using Analog Devices AD7747 sigma-delta capacitance to digital converter. The response of a MEMS capacitive accelerometer to various tests is useful for testing and characterization and investigate it’s suitability for various applications.
Authors: Aaditi Joshi, Sangram Redkar, Thomas Sugar
Institution: Arizona State University
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2346745324