Year: 2012
Type: article
Abstract: In this paper the two non-identical operative parallel cold standby systems has been analyzed by using regenerative point technique. The concept of inspection policy has been introduced for failed automatic unit for detecting the kind of failures (major or minor) after which it get repaired by some repair mechanism. But the manual one is free from inspection. The model has been design for the system to calculate the various important measures of reliability i.e MTSF, steady state availability, busy period of repairman and inspector, profit function using discrete distribution and regenerative point techniques. Profit function and MTSF are also analyzed graphically.
Source: IOSR Journal of Mathematics
DOI: 10.9790/5728-0115562
Author: JasdevBhatti JasdevBhatti
Language: English
Subfield: Safety, Risk, Reliability and Quality
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W2312290356