Estimation du métabolisme de travail à partir de mesures de fréquence cardiaque effectuées lors du travail forestier : réexamen d’aspects méthodologiques du point de vue du praticien
Year: 2014
Type: dissertation
Abstract: Work metabolism (WM) and maximal aerobic capacity (MAC) are fundamentals in the evaluation of the physical aspect of work in occupational ergonomics. Heart rate (HR) is often used to estimate WM and MAC from an individual HR to oxygen uptake (V ̇O_2) relationship establish on a submaximal test conducted in laboratory. An increase in core temperature due to prolonged workload or climatic load could lead to a substantial increase in HR, and therefore, an overestimation of WM. This increase in HR from heat stress should be taking into account if HR is to be used to estimate WM. Vogt et al. (1970, 1973) proposed a simple method to assess the heat stress contribution to HR (HR thermal component, ΔHR_T) in field setting. Yet, despite that the effect of heat stress on HR has long been recognized, the prediction bias associated with elevated HR from heat stress is unknown. Also, no study have compared WM prediction to actual WM when the thermal component is removed from raw HR. The first study aims to characterize the V ̇O_2 estimation error associated with heart rate (HR) measured during work and with HR corrected (thermal component removed) according to Vogt et al. (1970, 1973). Workday HR was monitored in 41 forest workers while performing brushcutting or tree planting work. 10-min seated rest periods were imposed during the workday to estimate the HR thermal component (ΔHR_T) according to Vogt et al. (1970, 1973). V ̇O_2 was measured using a portable gas analyzer during a morning submaximal step-test conducted at the work site, during a work session over the course of the day (range: 9 to 74 min), and during the following 10-min rest period taken at the worksite. The V ̇O_2 estimated, from measured HR and from corrected HR, were then compared to V ̇O_2 measured during work and rest. Varied levels of HR thermal component were observed (ΔHR_T avg range: 0 to 38 bpm). Using raw HR significantly overestimate measured work V ̇O_2 on average by 30% (range: 1% to 64%). 74% of V ̇O_2 prediction error variance was explained by the HR thermal component. V ̇O_2 estimated from corrected HR was not statistically different from measured V ̇O_2. Work V ̇O_2 can be estimated accurately in the presence of thermal stress using Vogt et al.'s method and can be implemented easily, with inexpensive instruments by the practitioner. The second study addresses four methodological questions faced by practitioners regarding the administration of a submaximal step-test in work settings and the accuracy of using the step-test heart rate to workload relationship to predict maximum aerobic capacity (MAC) and work metabolism (WM). Specifically, this study aims to answer: 1) what is the loss of accuracy in MAC and WM when using an equation predicting step-test V ̇O_2 values vs V ̇O_2 measurements during the step-test? 2) is the HR-V ̇O_2 relationship affected by wearing normal work clothes (vs light clothes) during a step-test? 3) if so, should the consequent HR increase be removed from the step-test data to improve MAC and WM assessments? 4) does the HR max prediction equation used affects the MAC estimate? This study make use of datasets collected in two experiments: one in laboratory to test MAC estimates and one during actual work (field study to test WM estimates using the Meyer and Flenghi (1995) submaximal step-test). Individual subject heart rate (HR) to workload relationships were determined through 93 submaximal step-tests administered to 26 healthy subjects attending physical activities in a University training center (Laboratory study) and 41 experienced forest workers (Field study). Maximum aerobic capacity (MAC) predicted with each subject's relationship was compared to measured MAC from a maximal treadmill test (Laboratory study) to test the effect of two age-predicted maximum HR equations (220-age and 207-0.7×age) and two clothing insulation levels (0.4 and 0.91 clo) during the step-test. Work metabolism (WM) estimated from forest work HR was compared against concurrent work V ̇O_2 measurements while taking into account the HR thermal component. Results show that MAC and WM can be accurately predicted (1% mean prediction bias with ±25% 95%LoA) from work HR measurements and simple regression models developed in this study. Clothing insulation had no impact on predicted MAC nor age-predicted maximum HR equations. The third study compares work metabolism estimation accuracy between two methods to assess the HR thermal component. Concurrent body core temperature, heart rate (HR), and energy expenditure were obtained during forest work. Methods previously described by Vogt et al. (1970; 1973) and Kampmann et al. (2001) were used to assess HR thermal component associated with body heat accumulation over a complete work day in 30 forest workers. The HR thermal component was deducted from the work HR data to obtain a thermoneutral HR profile from which work metabolism was estimated for n=15 workers. The two methods showed comparable average Thermal Cardiac Reactivity estimations of 26 and 31 bpm/˚C. Overall the method described by Vogt et al. (1970, 1973) provided a slightly better work metabolism estimation with a bias ± 95%LoA of 0.5 ± 4.4 mlO2/kg/min or 2.2% ± 21.6%. It was shown to be also simpler to implement, and it appears as a natural choice for the practitioner. The results obtained in this research project provided concrete answers to some methodological issues faced by the practitioner in the determination of work metabolism by means of heart rate measurements. These results also provide guidelines for the practitioner who is interested in work metabolism assessment in field settings.
Author: Philippe-Antoine Dubé
Institutions: Polytechnique Montréal, Université de Montréal
Language: French
Subfield: Physiology (medical)
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W238547752
