Thermal Analysis of Silty Sand Soil by Pipe Heater Installed in the Ground
Year: 2013
Type: article
Abstract: Three different mechanisms : line source model, commercial program(Temp/W) and filed test were used to analyse the thermal behavior of soil in this study. The results of in-site test were similar to line source model and program, the resulted graph showed log pattern curves. After 3 days of soil heating, the vapor emission was continuous with increased range of temperature whose radius is about 1m. The ground was excavated to examine with naked eyes where about 20cm range from pipe heater was completely sintered. Therefore, the soil heating through pipe in ground could be used to soil improvement successfully. In addition, the vapor caused by soil heating was emitted to upward and the most heat was transferred to horizontal direction.
Authors: Min‐Chul Park, 이금성, 장재호, 한희수
Language: Korean
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2269592978