Penetration Testing and Analyzing Defects on the Surface of Processed Stainless Steels
Year: 2014
Type: article
Abstract: When dye penetrant testing method is used to detect ZG04Cr13Ni4Mo stainless steel castings machined surface quality,we are able to observe round spots. In order to study whether such displayed dots indicate the presence of defect on machined surface,and which defect types they correspond to,penetrant testing methods have been adopted to detect machined surface defects of ZG04Cr13Ni4Mo stainless steel samples,and scanning electron microscope and metallurgical microscope are used to observe and analyze displayed dots. Test results show that displayed dots were observed on the sample surface. Dot size is in the range of 0. 07 ~ 1. 2 mm. After the samples are cleaned,scanning electron microscope was used to observe and analyze the imaging areas on sample surface. Defects are found on sample surface,which belong to inclusion defects. Defect size is in the range of 0. 07 ~ 1. 2 mm. These inclusions are rich in O,Si,Al,and Ca four elements.
Source: Harbin Ligong Daxue xuebao
Author: Xiaoru Wang
Institution: Harbin Electric Corporation (China)
Language: English
Subfield: Metals and Alloys
Field: Materials Science
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $581
OpenAlex ID: W2394095836