Year: 2016
Type: report
Abstract: Levels of 26 per- and polyfluoroalkyl substances (PFASs) were measured in 502 water samples originat-ing from Swedish groundwater, surface water, sewage treatment plant (STP) effluents and landfill leachates. In drinking water source areas, the average Σ26PFAS concentration was 8.4 ng L-1. The national drinking water guideline value of 90 ng L-1 for Σ7PFASs was exceeded in 2% of these samples. In water not used for drinking water, Σ26PFASs average concentration was 142 ng L-1. PFOS concentra-tions exceeded the Annual Average Environmental Quality Standard (AA-EQS) of the EU Water Frame-work Directive in 42% of the surface water samples. Among the different water categories, the landfill leachates had the highest average concentration of Σ26PFAS with 487 ng L-1, followed by surface water (average 112 ng L-1), groundwater (49 ng L-1), STP effluents (35 ng L-1) and background screening lakes (3.4 ng L-1). The composition profile of the PFASs differed between the types of waters showing an even distribution of ΣPFCAs, ΣPFSAs and ΣPFAS precursors in groundwater, whereas in all other water categories, ΣPFCAs were dominant. As FOSA, PFNA, PFDA, and 6:2 FTSA were frequently detected in drinking water source areas (constituted 20%, 7.3%, 5.9%, and 4.4% of the Σ26PFASs, respectively), it is reasonable to consider the inclusion of these in the Swedish drinking water guideline.
Authors: Lutz Ahrens, Johanna Hedlund, Wiebke Dürig, Rikard Tröger, Karin Wiberg
Language: English
Subfield: Environmental Chemistry
Field: Environmental Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2394622569