Work

Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition

Year: 2015
Type: article
Abstract: The low temperature distribution of the refrigerated and frozen food has been increased gradually. Refrigeration industry is using R134a refrigerant, which GWP is 1300. R1234yf is an alternative refrigerant of R134a because GWP of R1234yf refrigerant is just 4. Evaporator used in refrigeration truck refrigeration system is operated on low temperature condition. Accordingly, evaporator is formed frost and the formation of frost is rapidly decreased performance of evaporator. In this study, the performance of evaporator using R134a and R1234yf refrigerant was analyzed with operating conditions under frost condition. As a result, the performance of R134a evaporator according to air inlet temperature, relative humidity and evaporating temperature was more sensitive than R1234yf evaporator. Besides, the frost growth of R134a evaporator is steeper than that of R1234yf one.
Authors: Yunchan Shin, Jinhyun Kim, Honghuyn Cho
Language: English
Open Access status: bronze
OpenAlex ID: W2345465620
FWCI:
Cites: 7
Cited by:
Related to: 8