Work

Graded Spinal Cord Contusive Rat Model by a Weight-drop Device

Year: 2005
Type: article
Abstract: Objective: To investigate the reproducibility of graded spinal cord contusion by a weight-drop device, and to establish a graded spinal cord contusive rat model based on the functional analysis and morphometric measurement. Method: The weight-drop device developed was composed of impactor with a guidance rod, stereotaxic frame and spine stabilizing device. We investigated the reproducibility of impact by reliability analysis two weeks later. Thirty Sprague-Dawley rats were injured by the weight-drop device from the height of 12.5, 25.0 and 50.0 mm. The three groups of each drop-height (n=l0) as well as laminectomized sham group (n=l0) were subjected to functional analysis by Basso Beattie Bresnahan Locomotor Scales (BBB scales) and inclined plane test after contusion for four weeks. The morphometric measurement was performed at regularly spaced intervals including the epicenter according to the graded drop-height. Results: The impact of weight-drop was significantly increased according to the drop-height (p
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $153
OpenAlex ID: W2402003105
FWCI:
Cites:
Cited by:
Related to: 10