Work

Wearable microsensor technology to measure physical activity demands in handball: a reliability study of inertial movement analysis and player load

Year: 2015
Type: dissertation
Abstract: Purpose: Wearable microsensor technology allows for measurements of physical\nactivity in team sports. To use this technology with confidence, it is critical to determine\nits reliability. Therefore, the purpose of this study was to assess the reliability and\nsensitivity of a commercially available microsensor technology to measure physical\nactivity demands in handball.\nMethods: A total of twenty-two elite and sub-elite handball players (age, 22.6 ± 3.7\nyears; body mass, 84.0 ± 14.2 kg; height, 184.4 ± 12.0 cm; mean ± SD) were included\nin the present study. The subjects were instrumented with two devices (Optimeye S5,\nCatapult Sports, Melbourne, Australia), and participated either in a laboratory\nassessment (n =10) or field assessment (n = 12). The laboratory assessment consisted of\nseven different handball specific movement tasks, whereas the field assessment was\nconducted in twelve handball-training sessions. Various variables were extracted from\nthe manufacture’s software (Catapult Sprint, Catapult Sports, Melbourne, Australia)\nincluding Inertial movement analysis (IMA) magnitude and counts, and tri-axial\naccelerometer data (Player Load). The reliability between devices and sensitivity was\nestablished using coefficient of variation (CV) and smallest worthwhile different\n(SWD).\nResults: Laboratory assessment: IMA magnitude showed a good reliability (2.9%) in\nwell-controlled movement tasks. The CV increased (4.4 to 8.2%) in more chaotic\nmovement tasks. Field assessment: IMA counts showed a good reliability (CV 2.4%)\nwhen displayed as total counts. However, the CV increased when categorized in low\n(2.9%), medium (5.5%) and high (5.6%) intensity bands. Medium/high band\n(combined) showed a CV of 3.9%. The CV for low, medium/high and total counts was\nless than the SWD. Furthermore, it was observed a good reliability of Player Load\n(0.9%), which was less than the SWD.\nConclusion: The reliability of IMA counts was good, given that data were expressed as\nlow, medium/high and total counts. It was observed a good reliability for Player Load.\nThe CV of the aforementioned variables was well below the SWD, suggesting that\nOptimeye microsensors and its software are sensitive to detect “real and worthwhile”\ndifferences in handball activity.
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2470359946
Cites: 70
Cited by: 15
Related to: 9