Modeling and Optimization of an Integrated Column Sequence with In-Line Dilution for Continuous Chromatography of Proteins

Year: 2016
Type: dissertation
Abstract: In the pharmaceutical industry when proteins are being formed, the solution often consists of different kinds of proteins and these have to be separated to a high degree. A common process for this is chromatography. In this work a system of chromatography columns were coupled in series to separate a mixture of three proteins. The system consisted of three chromatography columns with mixers in between each column. The purpose was to see if in-line dilution of the mobile phase was a possible configuration to achieve compatibility between the columns. To investigate this, a model was constructed in MATLAB and simulation and optimization of the dilution was carried out. After the simulations and optimization were completed some experimental runs were performed to validate the results. The results showed that in-line dilution was a possible configuration and that a good yield and purity of the target protein could be obtained with the proposed system. The experiments also confirmed that in-line dilution was possible, however the results from the simulation and the experiments did not match. The required dilution between the columns from the optimization results was less than the dilution required in the experiments.