Work

Accuracy of two forms of early pregnancy diagnosis in cattle by ultrasonography

Year: 2015
Type: article
Abstract: The use of ultrasound in the diagnosis of pregnancy has been an indispensable tool for good reproductive performance. Pregnancy diagnosis via ultrasonography allows early detection of non-pregnant, allow the decision of turning it pregnant quickly, thus reducing the time that these animals do not remain pregnant. There are two ways diagnostic ultrasound for pregnancy: The first is the traditional view of the fetus and heart rate and the second is the observation of the amniotic bladder, characterized by the presence of fully anechoic content and distended uterine wall considered pathognomonic signs of pregnancy in cattle. The objective of this study was to evaluate the accuracy and execution time of these two forms of early ultrasound pregnancy diagnostic in cattle. We evaluated 674 crossbred cows used as embryo recipients in the same rural property, located in southern Minas Gerais. These were distributed randomly in two treatments: T1 (N = 351), diagnosis by detecting the amniotic bladder and T2 (n = 323), by browsing the fetus and heartbeat. All animals were between 28 and 32 days of gestation. The same equipment was used for both forms of diagnosis (Mindray M5 ™) with a transrectal transducer of 5 MHz. The examination of each run time was calculated using a digital timer. The pregnant females in both tests were reassessed by ultrasound considering the characteristics of the bladder and the presence of the fetus 30 days later. The data were evaluated by ANOVA. The differences in the percentage of pregnant females between 30 and 60 were compared using Fisher's exact test. It was considered significant, differences of below that 5% probability. The initial total pregnancy rate was 49.40% (333/674), of which 172 pregnant considered using the T1 and 161, using the T2. The difference between the total number of cows pregnant between 30 and 60 days was 5.70% and 5.88% for T1 and T2, respectively (P > 0.05), showing that the two methods have the same accuracy efficiency for pregnancy diagnosis at 30 days. The average running time of diagnosis was lower (P < 0.05) in T1 to T2 (0.5 ± 0.3 vs 1.8 ± 1.6 minutes). It is concluded that the two techniques of early diagnosis of pregnancy has the same accuracy after 30 days. As the female time of manipulation is lower in T1, this method should be indicated.
Language: English
Open Access status: gold
Estimated APC paid: $450
OpenAlex ID: W2508305976
FWCI:
Cites:
Cited by:
Related to: 10