Work

Myeloma minimal residual disease testing in the United States: Evidence of improved standardization

Year: 2016
Type: article
Study design: Observational Study
Abstract: To the Editor: An increasingly important question for treating hematologists/oncologists managing patients diagnosed with multiple myeloma is how to assess response to therapy beyond clinical response. Therefore, minimal residual disease (MRD) testing became increasingly important in assessing treatment response in patients with myeloma. MRD negativity by flow cytometry (FC) is consistently associated with improved progression-free and overall survival 1. This has prompted the Food and Drug Administration (FDA) to state that FC-MRD, if appropriately validated and standardized, could be used as a surrogate end point biomarker in clinical trials evaluating novel therapies 2. Variability in FC-MRD methodology and sensitivity, however, remains a challenge. In a survey from 2013, 11/26 U.S. medical institutions confirmed performing myeloma FC-MRD, with enormous variability in methodology, and a striking 100-fold difference in the sensitivity (limit of detection; LOD) 3. Subsequently, an international consensus process was undertaken to provide validated standardized methods for myeloma FC-MRD testing 4. We undertook a repeat survey to assess the current state of myeloma FC-MRD testing. A 17 question survey was e-mailed to the 26 institutions participating in the previous survey and responses compared to those received in 2013. The survey evaluated progress in FC methodology and the developing role of molecular MRD (M-MRD) testing for myeloma. Ninety-six percent (25/26) of institutions responded (Table 1). The number of institutions performing myeloma FC-MRD testing was increased (56%) compared to the previous survey (42.3%). All laboratories performing FC-MRD set a defined number of acquisition events for MRD detection (in contrast to only 9/11 in 2013). International consensus on myeloma FC-MRD detection stipulates a minimal acceptable cell acquisition number of 2,000,000 events (3,000,000–5,000,000 acquired events recommended) 5, 6. The number of laboratories acquiring ≥2,000,000 events increased tremendously (42.9%) compared to 2013 (9.1%). On the other hand, fewer laboratories are acquiring <2,000,000 events in this survey (57.1%) compared to the earlier survey (72.7%). As the LOD in FC-MRD testing is highly dependent upon the number of events acquired, improved LOD was demonstrated, with 6/14 (42.9%) laboratories achieving an LOD of 0.001% or better, in contrast to only 2/11 (18.2%) in 2013. Greater sensitivity is attained with technology utilizing a higher number of parameters/colors as it enhances the ability to differentiate normal from abnormal plasma cells. Three laboratories (21.4%) currently utilize 10-color FC (none did in 2013) and only 1/14 (7.1%) laboratories uses less than 8-color FC, compared to 6/11 (54.5%) laboratories in 2013. Specimens should be concentrated before staining to maximize cell yield for acquisition and to decrease antibody cost; therefore, erythrocytes lysing before staining (“pre-lyse”), and subsequent concentration of leukocytes is the preferred method 5. However, most laboratories performing FC-MRD (9/14, 64.3%) continue to stain un-concentrated cells followed by red cell lysis (“stain then lyse”), similar to the findings of the 2013 survey (7/11, 63.6%). Molecular methods, mainly based on next generation sequencing (NGS), were reported by five laboratories. Per the new IMWG response criteria 7, NGS is part of the approved testing platforms to determine MRD status. Based on ongoing development in the field, in the near future, it seems reasonable to believe that the use of NGS will continue to increase for the purpose of MRD testing. Indeed, NGS has fewer limitations and practical hurdles when it comes to standardization than FC-MRD has. Currently, a major limitation of NGS-based MRD assays is the restricted availability. In the near future, as new products become available, this is anticipated to be resolved. This survey shows that more institutions are implementing myeloma FC-MRD testing, with improved sensitivity/LOD. Areas for improvement include (1) defining a minimal acceptable cell acquisition number and (2) implementation of the recommended “pre-lyse” staining method. However, there are still areas for improvement to be done as only 6/14 laboratories acquire the minimal acceptable number of cells and only 5/14 utilize the optimal “pre-lyse” staining method. Ideally, a more standardized approach to myeloma MRD testing should hopefully be implemented. Standardization of FC-MRD in myeloma was recently included in the updated International Myeloma Working Group (IMWG) response criteria 7, allowing MRD to serve as an endpoint in clinical trials. This is important as it facilitates the development of MRD as a future surrogate regulatory endpoint for accelerated FDA approval of novel agents in myeloma treatment. The results of this survey are clinically relevant as they give a current update on the status of MRD monitoring in multiple myeloma in the US. Treating hematologists/oncologists managing myeloma patients need to stay aware of the rapidly evolving field and to ensure that their own patients are monitored with up-to-date assays. Dalia Salem,1 Maryalice Stetler-Stevenson,1 Constance Yuan,1 and Ola Landgren2* 1Flow Cytometry Unit, Laboratory of Pathology, Center for Cancer Research,National Cancer Institute, National Institutes of Health, Bethesda, Maryland; 2Myeloma Service, Department of Medicine, Memorial Sloan Kettering Cancer Center,New York, New York
Language: English
Subfield: Hematology
Field: Medicine
Open Access status: green
OpenAlex ID: W2508485999
FWCI: 3.486
Cites: 7
Cited by: 19
Related to: 10