Work

Immune cell self-organization towards ongoing immune reactions on a tissue-mimicking microdevice

Year: 2015
Type: dissertation
Abstract: A tissue mimicking micro-device has been developed by our microfluidics group. The device \nhas been designed in order to mimic complex in vivo scenarios of immune cell recruitment, \nwhere cells sense and are directed by soluble and structural signals in confined spaces. A \nmaze-structured network of microchannels is connected to cell culture chambers where immune \nreactions can take part. Immune reactions represent a source of chemoattractants molecules \nfor creating functional gradients across the network, possibly recruiting cells from other compartments. \nThe device is composed of a patterned structure of polydimethylsiloxane (PDMS), \nan organisilane elastomeric polymer, bonded on a glass coverslid. \nIn this work, our newly designed fourth generation device has been tested under several experimental \nconditions studies in order to determine its critical points in the study of cell \nchemotaxis. First, some of the microfabrication operations necessary for the realization of the \nchip have been expanded and partly translated to the biology laboratory. Good microfabrication \nprocedures have been proved to be fundamental for the functionality of the device, \nsince a good bonding between the micropatterned PDMS and the glass is crucial to spatially \ncontrol the flow of chemoattractant molecules. Second, a preliminary characterization of diffusion \ndynamics within the device was perfomed. The design fits the creation of gradients \nacross the mazed-structured network, but gradients seem to require time to be established. \nSome suggestion are therefore proposed in order to accelerate this process, such as increased \ndimensions of the attractor culture chambers, that are likely to help in the accumulation of \nmore chemokine-producing cells. In any case, some results suggest that established gradients \nmay be maintained during prolonged time inside the network. \nThe device was then employed in biological experiments showing potential recruitment of \nbone marrow-derived dendritic (BMDC) cells. These cells invaded the network under certain \nexperimental conditions and clearly localized towards the source of chemoattractant molecules. \nThe long time needed for gradient formation and a degree of unpredictability of the dynamics \nin antigen-presentation reactions ongoing on-chip, did not demonstrated active recruitment of \nCD8+ and CD4+ T cell hybridomas. T cell hybridomas showed thought a high motility inside \nthe device and interactions between them and BMDC have been documented in real-time. \nMoreover, the design fits the employement of several microscopy techniques that can be used \nto address diverse questions regarding mechanisms regulating cells’ routes and potentially (not \npresent in this work) subcellular events during migration. The design was proven to organize \nthe space surrounding migrating cells in a manner that is easily accessible to tracking and \nmodeling techniques. Temporal components of migration still need to be fully elucidated and \nwill require further work, also by coupling established biological assays, in order to fully benefit \nfrom device potentialities.
Language: English
Open Access status: green
OpenAlex ID: W2516849229
Cites: 60
Cited by:
Related to: 10