Work

Effect of high-frequency loading on peri-implant bone remodelling

Year: 2015
Type: dissertation
Abstract: Oral implants are titanium screw-shaped devices that are inserted in jaw bone to support a dental prosthesis. Osseointegration is required for their clinical success and implies direct bone apposition onto the implant. Despite high success rates of more than 90% after 15-years of follow-up, implants failures can occur in case of unfavorable conditions (e.g. compromised host bone, compromised blood circulation, low bone quantity, etc.). Instead of delaying the loading, there is currently a trend to functionally load implants immediately or early after implantation in order to limit the period of discomfort for the patients. Those faster loading protocols also lead to satisfactory success rates, but cannot yet predictably be applied in all clinical situations (e.g. low primary implant stability, low bone quality, etc.). Hence, it would be valuable to find a way to improve the reliability and speed, of implant osseointegration in order to optimize treatment outcomes also in compromised bone conditions. Mechanical loading is known to play a potent role in bone regeneration and adaptation. Recently, the interest in high-frequency mechanical loading, associated with low loading magnitude grows. Indeed, an increasing number of studies have shown their effect on enhancing bone formation in distraction osteogenesis and fracture healing of long bone. Clinical studies have shown an improvement of bone quality in both healthy and jeopardized conditions, such as in osteoporosis. The overall objective of this PhD research was to investigate the effect of mechanical loading, in particular high-frequency loading, on peri-implant bone healing and remodelling. More specifically, the tissue response under different loading frequencies/magnitudes or loading modes has been assessed. To investigate the response of healing versus healed peri-implant tissue to mechanical loading, the same loading was applied onto implants either immediately after implant insertion (immediate loading group) or after a healing time of 28 days (conventional loading group). Bone (re)modelling and vascularization in the peri-implant tissues were unaffected by both loading regimes. In the tissues of the implant’s vicinity, however, the observed gene expression changes were different in case of immediate versus conventional loading. Also an enhanced bone-to-implant contact was observed when loading was initiated immediately after implant insertion. In the following experiments, the effect of different immediate loading regimes was evaluated. The tested loading regimes differed in loading magnitude, frequency, duration, and mode (whole body vibration, direct and indirect implant loading). First, three consecutive experiments were performed to assess the effect of indirect high-frequency loading, via whole body vibration, on peri-implant bone remodelling. Both bone-to-implant contact and peri-implant bone density were significantly improved by the loading with a step-wise frequency band from 12 to 150 Hz at 0.3 g for around 10 min /day. When the loading session was shortened to 1 min 15 sec, 2 min 30 sec, 5 min and twice 1 min 15 sec (with 4 h interval) respectively, the improvements of bone-to-implant contact and peri-implant bone density were still significant, compared to the unloaded controls. Among the tested loading sessions, the loading with a load-free interval presented the highest gain of peri-implant bone. To investigate the optimized frequency and acceleration of whole body vibration, the vibration protocols of different combinations of loading frequency and acceleration were applied. For all combinations (i.e. 12-30 Hz at 0.3 g, 70-90 Hz at 0.3 g, 70-90 Hz at 0.075 g, 130-150 Hz at 0.3 g, and 130-150 Hz at 0.043 g), the loading combination with the highest frequency band and acceleration (e.g. 130-150 Hz at 0.3g) displayed the most favorable effect on BIC and BF, compared to the other test groups. Second, besides whole body vibration, another indirect loading protocol was performed thereby compressing an implant-containing long bone through its axis. The controlled compression was applied at both high- and low-frequency. Higher loading magnitudes (and accompanying elevated tissue strains) were required under low-frequency loading to provoke a positive peri-implant bone response, compared to high-frequency loading. A sustained period of loading at high-frequency was needed to induce overall enhanced effect on the peri-implant bone. After that, two studies were carried out to assess the effect of direct loading on peri-implant bone remodelling. In the first study, a small vibration motor was attached on the head of the implant to laterally stimulate the implant at 60±10 Hz. However, no pronounced bone response to the direct vibration was found. In the second study, a displacement-controlled loading was applied onto the implant through the implant axis. Four loading regimes were applied in this study: 1) HF-LM, 40 Hz-8 μm; 2) HF-HM, 40 Hz-16 μm; 3) LF-LM, 8 Hz-41 μm; 4) LF-HM, 8 Hz-82 μm. The stimulatory effect of immediate implant loading on bone-to-implant contact was only observed in case of high-frequency (40 Hz) low-magnitude (8 μm) loading. The applied load regimes failed to influence the peri-implant bone mass. This series of studies confirmed the role of mechanical loading in peri-implant bone regeneration and remodelling. Although an influencing role was observed for all loading modes, we tend to believe that the high frequency loading through WBV holds most potential.
Author: Xiaolei Zhang
Institution: KU Leuven
Language: English
Subfield: Oral Surgery
Field: Dentistry
Open Access status: green
OpenAlex ID: W2529888600
Cites: 217
Cited by:
Related to: 9