Year: 2012
Type: conference-paper
Abstract: With new demands for energy consumption in refurbished houses, some houses now need a vapour barrier although they could function without when the insulation was less. This is typically in ceilings; the traditional plaster ceiling was maybe airtight but open to vapour. Now the vapour must be stopped as well as the air. To install a vapour barrier in ceilings from the attic side can be very difficult, the obstacles are listed in the paper. This means traditional solutions are not robust to minor faults in the execution. Prefab fittings that can reduce the risk are on the marked, but they should be made more flexible to be useful for refurbishment, as the tolerances are bigger in existing than in new buildings. Furthermore, apprentices and skilled craftsmen should be trained by hands-on exercises where air leaks can be made visible. Guidelines should not only focus on new buildings but also give instructions for refurbishment. Finally the paper addresses the question whether all buildings must compile with the new energy requirements, or it is safer to allow some energy loss to prevent moisture problems.