Dispositivi protesici in Odontoiatria Digitale: dall'impronta digitale intraorale alla produzione con tecnologie Cad-Cam. Caratterizzazione in vitro della precisione di accoppiamento e delle proprietà meccaniche

Year: 2016
Type: article
Abstract: The objective of this work is to study some various aspects of the modern digital workflow to produce Fixed Dental Prostheses (FDP): from the optical impression, directly in the mouth, to the finalization of the prosthetic device specific for the patient. The motivation of this study is related to the growing need around the dental world to optimize and modernize the workflows that are still essentially artisanal. Taking advantage of modern digital technologies, that are rapidly spreading in the dental field, it is possible to obtain products with the highest quality standards, with lower production costs. Moreover it is important to spread the knowledge and skills to the dentists and to the dental technicians for an optimal use of these knowledges. In particular, we have have taken into consideration the following issues of distinct particular clinical importance: - optical intraoral scanning technology: specific operative and technical performance of these digital devices were investigated with particular reference to edentulous patients who need a full-arch implants rehabilitation, - innovative ceramic materials, used to produce metalfree multilayer bridges on natural teeth using Cad-Cam technology. It was also investigated an innovative resin composite material, which is also workable with Cad-Cam technology and used for the production of single crowns on implants. The revision of the scientific literature, suggested goals and metrological aspects of the experimental program of this research. The investigations, have evaluated precision and accuracy aspects of the optical impression of implants position, the geometric coupling precision of the multilayer metal free bridge components, mechanical resistance of different types of materials, and adhesion between a recent Cad-Cam resin composite referred as, Resin Nano-Ceramic (RNC) and zirconia. Moreover the introduction of instruments and methods established in the technical-scientific field, has been provided suitable to characterize the manufacturing processes used, the materials used and the devices manufactured. More in detail, the activities involved: 1. the study, in terms of metrological performance, of the acquisition process performed by the True Definition Scanner using a clinical sample reproducing a fully edentulous arch rehabilitated with 6 implants, 2. the verification of the geometric precision of the coupling component, sub and superstructure, of multilayer metalfree bridges made with different ceramic materials (zirconia-lithium disilicate), produced by Cad-Cam technology, and assembled by two different operators; the assembly / union of the bridge components, is instead carried out manually by the dental technicians totally handmade; 3. the analysis of the mechanical behavior, static, of the multilayer metalfree bridges, cited in paragraph 2, compared with another type of multilayer prosthesis (from the same Cad projects) but made with zirconia and glass ceramic (RLT), 4. the analysis by mechanical test, both static and under fatigue, of an innovative composite material resin supplied in blocks for Cad-Cam processing: Lava Ultimate. This new composite material presents, mechanical properties (Young's modulus), more similar to the natural tooth, compared to other aesthetic materials. For this reason, it was used to produce single crowns on implants comparing two different modes of use: cementing a composite crown produced with Cad-Cam technology directly on a titanium standard abutment supplied by industry, or producing a Cad-Cam zirconia customized abutment and cementing the composite crown to this; 5.verification of bonding capacity between zirconia and Lava Ultimate, using two different resin cements by means of shear bond test. Based on the results of the test campaigns conducted in this study it can be stated that: 1 technologies of digital intraoral optical impression are able to fulfill the clinical requirements of precision even in the case of full arch implants rehabilitations, 2. multilayer metalfree bridges, made with Cad-Cam technology according to the precision requirements of digital workflow, are affected by the intervention of the dental technician during the final assembly of the bridge components, resulting in reduced quality of precision established in the Cad phase, 3 multilayer metalfreee bridges show fracture toughness values greater than or equal to the minimum values reported in the scientific literature, 4. the implants crowns made with the innovative composite material subjected to strength tests and fatigue resistance, when cemented on an customized zirconia abutment, have superior mechanical characteristics than the cheapest solution, which provides the composite crown cementation directly to a standardized titanium abutment, 5. the use of adhesive cements for luting Lava Ultimate on zirconia, allowed to highlight the opposite results regards the strenght of adhesion, measured by means of the shear bond test.
Language: Italian
Field: Dentistry
Open Access status: green
OpenAlex ID: W2553396176
FWCI:
Cites: 273
Cited by:
Related to: 10