Year: 2016
Type: article
Abstract: Contemporary thermal diagnostic systems of power units require advanced computational tools, including mathematical models.These models should have a simple structure and short computing time. These conditions are satisfied by models thatinclude mass and energy balances as well as additional empirical functions whose coefficients are estimated by using themeasurement results. This paper presents a simulation model of an axial compressor which forms part of a gas turbineunit with a rated output of 125.4 MW. The model was developed with the use of a generalized compressor map, describingthe relationship between corrected air mass flow rate, pressure ratio, isentropic efficiency and corrected rotational speed.The model encompasses the empirical formula for compressor internal efficiency, which additionally considers the effect ofvariation of the angle of inlet guide vanes. The unknown values of empirical coefficients which appear in this equation wereestimated on the basis of operating data. The calculation results obtained were compared with the measurement results. Thequality of the model prediction was evaluated and conclusions were drawn.
Source: Journal of Power Technologies
Authors: Marcin Plis, Henryk Rusinowski
Institution: Silesian University of Technology
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2554496526