Work

SECOND-SOUND MEASUREMENTS ON a 3 GHz SRF CAVITY AT LOW ACCELERATION FIELDS *

Year: 2013
Type: conference-paper
Abstract: The superconducting Darmstadt electron linear accelerator S-DALINAC uses 20-cell niobium cavities that are operated at a microwave frequency of 3 GHz in liquid helium at a temperature of 2 K.This operation temperature is well below T C = 9.25K of niobium and guarantees superconducting condition in routinely operation.Occasional surface impurities, in particular after venting the beamline for maintenance work, can disturb the superconductivity and can lead to local break-downs of superconducting conditions.In such events it is desirable to have a method at ones disposal for locating and eliminating these surface impurities.In order to locate quench sites on the superconducting cavities during operation in liquid helium a set-up using Oscillating Superleak Transducers (OSTs) was developed and tested in a vertical bath cryostat.For the experiments we used a cavity known to quench at very small accelerating fields.Despite the low rf power of approximately 4 W needed to quench the cavity, we were able to locate the quench sites with the OST set-up.Subsequent optical inspection clearly showed surface damages at the determined positions.We will report on our set-up and procedure.
Language: English
Open Access status: green
OpenAlex ID: W2557571539
FWCI:
Cites: 5
Cited by:
Related to: 10