Abstract: Scoliosis is a pathology that causes a three-dimensional deformation of the spine and rib cage. This disease usually appears during adolescence and “large progression” cases affect females 90% of the time. Adolescent idiopathic scoliosis has a prevalence of 3% to 5%, and around 10% of patients require a treatment. For severe spinal deformities, the main treatment is to surgically correct the spine by instrumentation. Screws are inserted into the vertebrae through the pedicles and are used to apply surgical maneuvers in order to align the column, after which instrumentation rods are attached to stabilize the spine. The short-term goals are to reduce the spinal curvature; the long-term goals are to stiffen the spine and promote arthrodesis. The pedicle screws undergo significant and variable forces during correction maneuvers and also after surgery while the patient undergoes functional movements, which can cause partial or total loosening of the screw construct. A strong connection between the screws and vertebrae is needed to ensure a safe correction. The biomechanical anchorage of pedicle screws depends on the intrinsic parameters of the vertebrae (shape and size of the vertebrae, bone density and bone distribution), but also on the surgical insertion techniques of screws such as the trajectory or amount of bone removed at the insertion point. However, the design (thread design and type), the choice of the size of the implants, and insertion technique (preparation of the entry point, the diameter or tapping diameter) still depend on empirical principles and on the surgeon's experience. Many studies have determined the effects of the main parameters affecting the pedicle screw anchorage, but due to the destructive aspects and the high experimental variability, only a few were able to compare relevant parameters. Moreover, most experimental tests are done with axial pullout forces, which do not fully represent the possible forces that are applied on the screws during surgical maneuvers or postoperatively. Non-axial loading tests are yet not standardized, which makes comparison between studies more complex. Many studies have investigated pedicle screw behaviour using finite element modelling. However, there is currently no model refined enough that can represent in detail the behaviour of pedicle screws, bone structures, and the contact interface during intraoperative loadings.
Author: Rohan Bianco
Institutions: Polytechnique Montréal, Université de Montréal
Language: French
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2567519604