Work

Virtual vitreoretinal surgery: construction of a training programme on the Eyesi Surgical Simulator

Year: 2016
Type: conference-paper
Abstract: Purpose: The purpose of this study was to test the construct validity of a full virtual reality vitreoretinal training program at the Eyesi Surgical simulator. Design and methods: A virtual vitreoretinal training program was composed on the Eyesi Surgical simulator, software version 2.9.2 (VRmagic GmbH, Manheim, Germany). It was completed twice by three groups: Group 1: Twenty medical students Group 2: Ten ophthalmology residents Group 3: Five vitreoretinal surgeons The program consisted of six training modules (Figure 1): Navigation level 2 (Nav2) Forceps Training level 5 (ForT5) Bimanual Training level 3 (BimT3) Laser Coagulation level 3 (LasC3) Posterior Hyaloid level 3 (PostH3) Internal Limiting Membrane Peeling level 3 (ILMP3). Construct validity for a module was obtained if the median score for Group 3 was higher than for Group 2, which in turn was higher than for Group 1.This was tested by Kruskal Wallis test by ranks. Results: The participants achieved higher overall score in Group 3 than Group 2 and Group 1 (Table 1). The same applied to sub score where the participants in Group 3 scored higher than Group 2 and Group 1 in Nav2, BimT3, PostH3 and ILMP3 (Table 1). Conclusions: We developed a training program in virtual vitreoretinal surgery with construct validity for four out of six modules and for overall score. This makes the program a useful tool in the training of future vitreoretinal surgeons.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
OpenAlex ID: W2574604751
FWCI:
Cites:
Cited by:
Related to: 9