Impact of the new Chilean air-tightness regulation on indoor air pollution in dwellings with inefficient heating sources
Year: 2016
Type: conference-paper
Abstract: In 2014, the Chilean Ministry of Housing and Urban Planning (MINVU) began to develop regulations for maximum levels of air infiltration in dwellings. This paper investigates the impacts of increased air-tightness on indoor air quality (IAQ) and energy use. The study uses computer simulations representative of social housing in Temuco, a city with heavy urban air pollution and cold winters. Results show infiltration measures produced reductions of -49% in air changes and -17% in heating loads. Emissions from six different types of wood, gas and paraffin burners including PM10, PM2.5, NO2, CO, SO2 and PAHs were modelled. changes of between -3% to +35% in individual contaminant concentrations, revealing that increased air-tightness does not necessarily imply a reduction in IAQ due to variations in deposition rates and reduced external pollutant ingress. As heater emissions exceeded pollutant concentration limits between 1-41% of the time, adopting cleaner heating technology is recommended
Authors: Shrubsole, C, Narváez, R, Altamirano-Medina, H
Language: English
Subfield: Health, Toxicology and Mutagenesis
Field: Environmental Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2587792897