Arsenic(V) Removal From Drinking Water By Concurrent Introduction Of As Contaminated Water And Polyaluminum Chloride In A Sand Filter Medium
Year: 2016
Type: dissertation
Abstract: Arsenic is a toxic element and may be found in groundwater, thus, proper treatment is required for arsenic contaminated groundwater before its use as drinking water.The present study describes removal of As(V) by contact filtration on sand media using Polyaluminum chloride (PACl) as coagulant.Arsenic--contaminated water and PACl coagulant were introduced concurrently into a sand filter column.A PACl dose of 15 mg/L as aluminum reduced the As concentration in a synthetic groundwater (pH=8) from 100 ppb to less than 10 ppb.The 81 cm deep single sand column treated 38.4 pore volumes before it reached the maximum allowable experimental head loss (450 cm).Reducing the PACl dose resulted in an increased As concentration in the filter effluent.The PACl precipitate--As complex could be removed from the filter by backwash.Results suggest precipitated PACl nanoclusters are more efficient than aluminum oxide/hydroxide solid phases in As removal.Filter performance was shown to be independent of how the PACl was distributed in the filter column.
Source: eCommons (Cornell University)
Author: Hui Zhi
Language: English
Subfield: Environmental Chemistry
Field: Environmental Science
Domain: Physical Sciences
Open Access status: green