Abstract: Slip stacking injection for high intensity operation of the Fermilab Main Injector produces a small fraction of beam which is not captured in buckets and accelerated. A colli-mation system has been implemented with a thin primary collimator to define the momentum aperture at which this beam is lost and four massive secondary collimators to cap-ture the scattered beam. The secondary collimators define tight apertures and thereby capture a fraction of other lost beam. The system was installed in 2007 with commis-sioning continuing in 2008. The collimation system will be described including simulation, design, installation, and commissioning. Successful operation and operational lim-itations will be described. HIGH INTENSITY OPERATION
Author: Bruce Brown
Language: English
Open Access status: green
OpenAlex ID: W2600847280
FWCI: 0.252
Cites: 3
Cited by: 3
Related to: 9