A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Year: 2017
Type: article
Abstract: A model-based method for interturn short-circuit fault detection and isolation in permanent magnet synchronous machines (PMSMs) is proposed in this paper. The fault detection is realized based on a residual current vector (RCV) generated by the difference between the measured stator currents and the stator currents estimated by a state observer. In order to avoid false alarms due to possible undesired perturbations, the sequence decomposition of the RCV is performed by employing different reference-frames. Thus, the proposed RCV allows the correct detection of interturn short-circuit faults and quantification of the fault severity in any faulty stator-phase winding. Moreover, since the back-EMF generated by the magnets is proportional to the rotor shaft speed, the electrical angular speed is estimated through the stator voltages measurement, without using a speed sensor. Simulation results from the three-phase PMSM dynamic model that allows considering the interturn short-circuit fault in any stator phase-windings are presented. The proposed method is validated using a three-phase PMSM prototype with modified stator windings. The robustness and the reliability of the proposal was tested for several interturn fault conditions under transient conditions including different disturbances.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Keywords: inter-turn short-circuit fault, permanent magnet synchronous motor, fault diagnosis, fault detection and isolation, state observer, sequence decomposition, sensorless speed estimation, back electromotive force, stator winding faults, fault severity quantification, model-based fault detection
Open Access status: green
OpenAlex ID: W2602794282