Modeling and prediction of watershed-scale dynamics of consumptive water reuse for power plant cooling
Year: 2016
Type: article
Abstract: The energy-water nexus -the relationship between energy and water resources -is an area of emerging concern among resource managers, policy makers, and academics [1-6].Of particular interest in Illinois is the overlap between thermoelectric power plants, which require cooling to condense process steam, and water resources.In Illinois, thermoelectric power plants (using primarily coal and nuclear fuels) account for over 85% of freshwater withdrawals [7].Since many of those facilities use open-loop (or once-through) cooling with lower consumptive demands, they only consume an estimated 2% of the water withdrawn [8]; however, nationwide water consumption data have not been reported since 1995.As water resources endure strain from additional demands and changing climate, researchers and resource managers have considered use of alternative water supplies, such as reclaimed water from municipal wastewater treatment plants (WWTPs) [9][10][11].Reclaimed water can be a drought-resistant, non-potable water source for power plants, decreasing water demand conflicts with other users and reducing thermal loading on major rivers, such as the Illinois River with several power plants in series.However, since reclaimed water use typically requires cooling towers instead of open-loop cooling, water reuse for power plants could increase water consumption via evaporation along with additional capital cost for infrastructure.Our work modeled water reuse at select thermoelectric power plants in Illinois, and estimated the watershed-scale dynamics of additional water consumption.While water reuse for power plants can be a beneficial water management approach locally, the additional water consumption might have significant negative impacts downstream for other water users, including navigation.To model and quantify these conditions, we completed the following research objectives in the study area shown in Figure 1 and described in Table 1: 1. Evaluate the degree of de facto water reuse at power plants in the study area, based on the incidental presence of wastewater effluent in the natural water source.a 1,440 68.9 --US$31.5 US$31.5 Kendall County 1,260 Natural Gas Closed-loop --0.2 --US$0.09US$0.09 4. a Has facilities to operate as closed-loop but primarily utilizes open-loop cooling. 5. b Estimated as $984 per million gallons [12].
Authors: Ashlynn S. Stillwell, Zachary A. Barker
Language: English
Subfield: Water Science and Technology
Field: Environmental Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2614457217