Diagnostic Accuracy of Computed Tomography–Derived Fractional Flow Reserve: A Systematic Review
Year: 2017
Type: article
Abstract: Importance: Computed tomography-derived fractional flow reserve (FFR-CT) is a novel, noninvasive test for myocardial ischemia. Clinicians using FFR-CT must be able to interpret individual FFR-CT results to determine subsequent patient care. Objective: To provide clinicians a means of interpreting individual FFR-CT results with respect to the range of invasive FFRs that this interpretation might likely represent. Evidence Review: We performed a systematic review in accordance with guidelines from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. A systematic search of MEDLINE (January 1, 2011, to 2016, week 2) and EMBASE (January 1, 2011, to 2016, week 2) was performed for studies assessing the diagnostic accuracy of FFR-CT. Title words used were computed tomography or computed tomographic and fractional flow reserve or FFR. Results were limited to publications in peer-reviewed journals. Duplicate studies and abstracts from scientific meetings were removed. All of the retrieved studies, including references, were reviewed. Findings: There were 908 vessels from 536 patients in 5 studies included in the analysis. A total of 365 (68.1%) were male, and the mean (SD) age was 63.2 (9.5) years. The overall per-vessel diagnostic accuracy of FFR-CT was 81.9% (95% CI, 79.4%-84.4%). For vessels with FFR-CT values below 0.60, 0.60 to 0.70, 0.70 to 0.80, 0.80 to 0.90, and above 0.90, diagnostic accuracy of FFR-CT was 86.4% (95% CI, 78.0%-94.0%), 74.7% (95% CI, 71.9%-77.5%), 46.1% (95% CI, 42.9%-49.3%), 87.3% (95% CI, 85.1%-89.5%), and 97.9% (95% CI, 97.9%-98.8%), respectively. The 82% (overall) diagnostic accuracy threshold was met for FFR-CT values lower than 0.63 or above 0.83. More stringent 95% and 98% diagnostic accuracy thresholds were met for FFR-CT values lower than 0.53 or above 0.93 and lower than 0.47 or above 0.99, respectively. Conclusions and Relevance: The diagnostic accuracy of FFR-CT varies markedly across the spectrum of disease. This analysis allows clinicians to interpret the diagnostic accuracy of individual FFR-CT results. In combination with patient-specific factors, clinicians can use FFR-CT to judge when the cost and risk of an invasive angiogram may safely be avoided.
Source: JAMA Cardiology
Institution: Imperial College London
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
Awards: Ischaemia-induced electromechanical delay for the diagnosis of coronary artery disease, G5458636982, Experimental manipulation of indices of lesion severity in multi-vessel coronary artery disease: Quantitative exploration of collateral influences., The development and implementation of automated methods for the reproducible assessment of aortic stenosis and mitral regurgitation, Developing and studying diagnostic and therapeutic techniques for heart failure and other cardiac diseases, by application of engineering and mathematical principles
OpenAlex ID: W2618197121