Work

Characterization of novel preclinical dose distributions for micro irradiator

Year: 2017
Type: conference-paper
Abstract: This work explores and demonstrates the feasibility of utilizing new 3D printing techniques to implement advanced micro radiation therapy for pre-clinical small animal studies. 3D printed blocks and compensators were designed and printed from a strong x-ray attenuating material at sub-millimeter resolution. These techniques enable a powerful range of new preclinical treatment capabilities including grid therapy, lattice therapy, and IMRT treatment. At small scales, verification of these treatments is exceptionally challenging, and high resolution 3D dosimetry (0.5mm 3 ) is an essential capability to characterize and verify these capabilities, Here, investigate the 2D and 3D dosimetry of several novel pre-clinical treatments using a combination of EBT film and Presage/optical-CT 3D dosimetry in rodent-morphic dosimeters.
Institution: Duke Medical Center
Language: English
Subfield: Radiation
Open Access status: diamond
OpenAlex ID: W2624461531
FWCI:
Cites: 8
Cited by:
Related to: 10