Year: 2007
Type: article
Abstract: This work describes a deep penetration problem where a design change resulted in higher than anticipated calculated doses to x-ray machine operators.Following an analysis of the gamma spectra, the source of the increase in dose became apparent.The increase in dose was due to low energy scatter around the shields that had previously been attenuated by a door that was removed due to the design change.The door, while thin, removed most of the low energy scattered photons.The methodology developed may be used as a guide for future calculations of similar construction.
Institution: Los Alamos National Laboratory
Language: English
Subfield: Materials Chemistry
Field: Materials Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2625747209