Work

Modelación del proceso de biofiltro percolador para el tratamiento de emisiones en aire de Compuestos Orgánicos Volátiles de elevada solubilidad en agua

Year: 2016
Type: dissertation
Abstract: Air pollution produced by the emission to the atmosphere of volatile organic compounds (VOCs) is one of the most important causes associated with deterioration of air quality. One of the main sources of VOC emissions are companies that use solvents. In this regard, they should make an effort to adapt their production processes in order to minimise environmental impact. However, the properties of solvents make them essential in certain applications, so the treatment of derivative emissions becomes a necessity. Use of biotrickling filters for the removal of highly water soluble VOCs is a sustainable technology, having been proven to be technologically and economically a viable alternative, as supported by research in the last few decades. However, research development on this technology requires one further step to achieve consolidation in the industrial environment. The main objective of this dissertation is to develop a mathematical tool that includes the principal mechanisms involved in the removal of VOCs of high solubility in water from air emissions by the biotrickling filtration process in typical industry operating conditions. VOCs of high solubility in water are usually present in gaseous emissions from the flexographic printing industry, among others. Despite being compounds with a relatively high biodegradability, biological removal of such compounds is often limited by oxygen availability within biofilm, which leads to pollutant accumulation within the system. In this regard, an important part of the thesis was focused on the study of the mechanisms of mass transfer of pollutants and oxygen by means of the determination of the mass transfer coefficients for both compounds. The mathematical tool developed here aims to simulate and predict the transient response of the biotrickling filters under variable loading conditions and intermittent spraying. The mathematical model has been applied to biotrickling filters used in the laboratory, under controlled operating conditions, as well as to biotrickling filters located in industrial facilities, in which more buffered emission patterns are observed. The first stage of this work comprises the removal of isopropanol in air emissions at the laboratory scale, selected as a model pollutant. For this purpose, two biotrickling filters filled with different packing materials were used: a random one and a structured one. The reactors were operated under discontinuous loading conditions and intermittent spraying. The response of the biotrickling filter to variations in the inlet concentration of pollutant, as well as in the gas flow, was evaluated. The results showed that intermittent spraying caused a fugitive pollutant emission in the outlet gaseous stream of the biotrickling during spraying. To evaluate this effect, different spraying conditions were tested, concluding that the spray pattern could be used as a strategy to increase the reactor performance. Likewise, a starvation period of seven weeks was applied to both reactors. The resilience of the biotrickling filters showed the robustness of the system. The next stage was focused on the study of mass transfer in biotrickling filters. For this purpose, the mass transfer coefficients of oxygen and of isopropanol were determined. Different superficial gas and liquid velocities as well as different packing materials were tested. Results allowed empirical correlations to be established, which characterised the relationship between the mass transfer coefficients and superficial velocities of liquid and of gas applied to the biotrickling filters. Likewise, a packing material for industrial use was evaluated in terms of oxygen mass transfer, in order to compare it to the packing materials applied in the laboratory. At typical industrial operating conditions, oxygen mass transfer for the industrial material was found to be similar to those obtained for the laboratory packing materials. In the final stage, a mathematical model was developed in order to predict the transient response of the biotrickling filters under non-steady conditions of pollutant loading and of intermittent spray. The model development was based on the mass balances of isopropanol and of oxygen in the gas phase, in the liquid phase and in the biofilm. The mathematical model was built assuming cyclic conditions of spraying/non-spraying periods, the common industrial operational protocol. During spraying periods, a mobile liquid phase was considered, while during non-spraying periods, a stagnant liquid phase was considered. The calibration and validation of the mathematical model was performed using data from biotrickling filters operated at laboratory and industrial scales. The main hypotheses of the model were related to mass transfer resistance during spraying (mobile liquid phase) and mass transfer resistance during non-spraying (stagnant liquid phase). Model calibration was carried out with laboratory biotrickling filters operated under discontinuous spraying and intermittent pollutant loading. By assuming negligible mass transfer resistance for the stagnant liquid phase during non-spraying, the model was able to reproduce the average system performance and the emission pattern occasioned by the discontinuous spraying. In addition, the relationship between VOC concentration in the recirculation tank and the fugitive emission observed during spraying periods was related to higher mass transfer resistance between the gas and the mobile liquid phase during spraying than that obtained during abiotic determinations. This phenomenon was associated with variations in the physical properties caused by the presence of biofilm. The model application for predicting outlet emissions of a biotrickling filter installed in the flexographic printing industrial facility demonstrated its practical usefulness. Model application for simulating this industrial air flow was based on the hypotheses of mass transfer resistance for the mobile liquid phase during spraying and an additional mass transfer resistance from the stagnant liquid phase during non-spraying with respect to laboratory experiments. It was identified that the biofilm acted as a source/sink associated with daily periods of manufacturing/ non-manufacturing. Thus, a greater thickness of biofilm than in the laboratory biotrickling filters was fixed. The thick biofilm caused the accumulation of the non-degraded pollutant during periods with VOCs feeding to the system. The stored pollutant in the biofilm led to desorption during periods when clean air circulated through the reactor. The model capability to reproduce the complex phenomena involved in the dynamic response of the biotrickling filters treating volatile organic compounds with high water solubility was demonstrated. The mathematical model was integrated into an informatics tool using a GUI (Graphical User Interface) developed with MATLAB®. In order to facilitate communication with the end user, two interfaces were generated: an interface to enter data for simulations, and a results interface. The developed tool allows for the introduction of variable patterns of concentration and gas flows in a simple way, and also the use of intermittent spraying patterns. When the simulation ends, the tool offers a results screen with the most relevant information to evaluate the performance of the biotrickling filters: graphic information regarding the pattern of the gaseous emissions at the inlet and at the outlet of the reactor, as well as graphic information regarding the variation of dissolved organic carbon in the recirculation tank. Average data regarding the concentration in the gaseous emission at the inlet and at the outlet of the bioreactor, and the inlet load and the elimination capacity, are also provided.
Language: Spanish
Open Access status: green
OpenAlex ID: W2625911472
Cites: 80
Cited by:
Related to: 10