Homogeneous and Heterogeneous Resonators in Ultrahigh-Field MRI

Year: 2011
Type: article
Abstract: The main objective of this study was to construct, to improve and to evaluate the performance of different radiofrequency (RF) coils for ultrahigh-field (UHF) at 7T magnetic resonance imaging (MRI) with respect to signal-to-noise ratio (SNR), B1 homogeneity, and effective flip angle (FA) maps. Best magnetic resonance (MR) images are obtained if RF coils fulfill the two fundamental requirements: the B1 field in the excited volume respective region of interest (ROI) has to be homogeneous while the received SNR has to be as high as possible. However, the major problems associated at UHF conditions are amplified imaging artifacts, the shortened transversal relaxation times of tissue, the inhomogeneous B1 field in the ROI, and the increased absorption of RF energy. Although all RF coils in UHF MRI intrinsically generate inhomogeneous B1 fields due to the dielectric effect rather than the RF coil geometry, each RF coil may exhibit special characteristics, which makes them optimized for special MRI applications. They should therefore be designed according to the desired field of operation to obtain optimal performance MRI. The developed UHF RF coils were categorized according to their architecture, i.e., into homogeneous and heterogeneous coils. Four homogeneous transmit/receive (Tx/Rx) circular polarized (CP) volume coils - hybrid birdcage (HBC), hybrid spiral birdcage (HSBC), dual Helmholtz (DH), and slotted tube (ST) - were constructed, compared and evaluated at a magnetic field strength of 7T. An evaluation procedure for comparing the B1 field inhomogeneity and SNR is proposed. In particular, B1 excitation inhomogeneity has to be considered and compared between the different RF coils to improve the differences in the contrast and the spatially varying image signal in the ROI. Heterogeneous coils such as surface coils are usually much smaller than homogeneous coils. They are located nearer the object and hence usually have higher SNR because they receive higher signal from the ROI. However, they have a relatively poor B1 field homogeneity, and thus, they are mainly utilized as Rx-only coils. In an additional stage, a 16 element parallel Tx (pTx) coil was designed, constructed and evaluated for use as a head-array. The RF coil was connected to a 16 × 16 Butler matrix network operated by an eight-channel parallel Tx system to investigate the improvement of the B1 excitation. The transmit profiles were evaluated for various clockwise CP modes with respect to homogeneity. Compared to the CP coil architectures the 16 element pTx coil provides much more potential to improve excitation characteristics.
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2630533617
FWCI:
Cites: 100
Cited by: 2
Related to: 10