Work

Towards patient-specific dose and image quality analysis in CT imaging

Year: 2017
Type: dissertation
Abstract: As opposed to conventional radiography, computed tomography provides 3D information of the anatomical structures and tissues of the patient, at a much better low-contrast performance. However, radiation doses associated with CT are up to 40 times higher compared to conventional X-ray examinations. In addition, the number of scans performed increases every year. Since a small but significant risk of radiation induced malignancies is associated with exposure to ionizing radiation, CT imaging must be optimized to assure the required diagnostic level of image quality (IQ) at the lowest possible dose. The aim of this PhD work was to assess the performance of CT systems in terms of patient dose and IQ. To this end, Monte Carlo simulations were performed with voxelized phantoms, based on clinical CT data. IQ was evaluated by means of an automatic scoring algorithm based on local standard deviations. Using the proposed methods, the behaviour of tube current modulation (TCM) techniques was investigated. In addition, a simplified approach for patient-specific organ dose calculation and risk estimation was developed for use in clinical practice. To reduce patient radiation dose and to optimize IQ in CT imaging, tube current modulation (TCM) systems were developed. By modulating the tube current along the length axis of the scan, a constant IQ level can be obtained throughout the patient. The tube current is adapted based on a projection radiograph, taken prior to the CT acquisition in either the anterior–posterior (AP), posterior–anterior (PA) or lateral (LAT) direction. As a result, exposure values will be lowered in less attenuating or smaller anatomical regions. In this work, the influence of the localizer type and the scan direction on the dose reducing efficacy of TCM systems was investigated. Chest CT scans based on AP, PA, LAT or dual AP/LAT localizers were acquired on systems from 3 different vendors. In addition the scan direction was changed for one particular system. Organ doses were calculated with Monte Carlo simulations and validated in an anthropomorphic phantom. Thyroid and lung doses increased with 60% for a PA- instead of dual AP/LAT-based scan, with significant differences in image noise. In addition, the thyroid dose halves by taking the scan in the caudocranial (feet first) direction. IQ was not significantly different when changing the scan direction. Our results demonstrate a strong need for detailed analysis of the TCM system performance during commissioning of CT scanners.
Author: Caro Franck
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2729668486
Cites: 97
Cited by:
Related to: 10