Work

Three-dimensional guidance for Endovascular Aortic Repair

Year: 2017
Type: dissertation
Abstract: Image fusion (IF) of preoperative computed tomography (CT) with intraoperative cone-beam CT (CBCT) is a potentially powerful tool for guidance during endovascular aortic repair (EVAR). It may improve intraoperative anatomic visualization and reduce doses of radiation and contrast medium. The technique is still new, however, and has not yet been standardized for routine use in all centers that have the facilities to perform it.\n\nThe main aims of this thesis were:\n\n1. to describe the use of orthogonal rings for 3D guidance during EVAR and to investigate sources of registration and overlay error;\n\n2. to investigate the feasibility of combining 3D fusion with carbon dioxide (CO2 ) digital subtraction angi-ography (DSA) during EVAR, in order to reduce the dosage of iodinated contrast;\n\n3. to determine whether 3D image fusion can be used to localize intercostal arteries during thoracic EVAR; 4. to evaluate the performance of a feature-based algorithm for 3D3D image registration; and\n\n5. to assess iliac artery deformation due to stiff endovascular devices during EVAR.\n\nIn a prospective single-center study (I) involving 19 patients undergoing EVAR, we found that automatic intensity-based registration only was insufficient for guidance. Manual vertebrae-based registration was sufficient in only 37% of the patients. After aorta-based registration, the median overlay alignment error for the lowest renal artery at pre-deployment DSA was 2 mm (range 0‒5 mm) sideways and 2 mm (range 0‒9 mm) longitudinally.\n\nStudy II was a feasibility study showing that EVAR can be performed with 3D image fusion guidance combined with CO2 DSA, instead of iodinated contrast medium DSA, which was only used for the completion angiography.\n\nStudy III was also a feasibility study showing that image fusion can facilitate thoracic EVAR (TEVAR) by visualization of intercostal arteries adjacent to the distal landing zones.\n\nIn study IV, a feature-based and an intensity-based registration algorithm were compared using datasets from 14 patients who underwent complex EVAR. The feature-based algorithm was more robust and accurate. The median 3D error for the feature-based algorithm was 2.3 mm (range 0.4‒7.9 mm) as compared to 31.6 mm (range 0.5‒112.2 mm) for the intensity-based algorithm (p < 0.001).\n\nIn study V, preoperative, postoperative, and intraoperative 3D image datasets were reviewed in order to assess iliac artery deformation by stiff endovascular devices during EVAR. The common iliac artery was shorter in both the intraoperative images (p < 0.001) and the postoperative images (p = 0.015) relative to the preoperative CTA. Furthermore, there was a dislocation of the aortic bifurcation in the cranial direction (93%) and a dislocation of the iliac bifurcation in the ventral direction (89%). The intraoperative C-arm angulation for optimal projection of the iliac bifurcation increased with 21 ± 43 degrees in the contralateral oblique direction relative to the angle predicted from the preoperative CTA.\n\nIn conclusion, 3D image fusion for EVAR guidance is a promising technique allowing improved intraoperative visualization of critical anatomical structures. However, limitations in registration accuracy and anatomy distortion compensation mandate further research.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: green
OpenAlex ID: W2756878096
Cites: 98
Cited by: 1
Related to: 10