Determination of the Infection Risks Posed by the Use of Mobile Technology in Healthcare Settings
Year: 2017
Type: dissertation
Abstract: There are more mobile phones in the world than there are people, and numbers are \nincreasing. Immediate access to technology has completely permeated everyday life, and \nfor many people their mobile devices are an indispensable accessory that accompanies them \neverywhere, including the bathroom. Mobile devices can harbour pathogenic \nmicroorganisms on their surfaces, that can survive for days, before potentially being \ntransferred onto hands or other objects that they come into contact with. These devices are \nalso rarely decontaminated. Whilst these microorganisms are generally not of concern to the healthy adult, they may be to the very young, the elderly, and those with reduced \nimmunity. \n \nThis study determined if mobile devices can be used in the healthcare setting and not be an \ninfection risk. A six-stage mixed methodology approach was employed, with laboratory \ninvestigations into the contamination on mobile devices, the efficiency of transfer from \nthem, and the effectiveness of decontamination methods. Analysis of existing NHS mobile \ndevice policy and application of the Hazard Analysis Critical Control Point process to \nperioperative practice provided real-world perspective. \n \nThe findings from this study identified that current literature is under-reporting the \ncontamination on mobile devices, and determined that the bacterial presence is transient, \nnot constant. Transfer efficiency of up to 79% was recorded for Staphylococcus aureus from \na device onto a wet gloved hand, and observation of perioperative practice identified five \nhazards specific to the presence of a device, that could become a risk to patient safety, but \ncould be managed through application of Critical Control Points. This study also found that \nover 40% of NHS organisations in mainland UK do not have a mobile device policy, and only \n11% make any reference to their infection prevention and control. Testing of \ndecontamination methods determined that a two-stage process of wiping with a dry lint-free \ncloth, followed by exposure to UV-C, was the only approach that effectively reduced \ncontamination levels without contradicting manufacturers’ guidance and thus voiding the \ndevice warranty. Optimum criteria for mobile device policy, and suggestions for in-context \napplication, are proposed.
Author: Stephen White
Institution: University of Huddersfield
Language: English
Subfield: Infectious Diseases
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2758932594