Work

Resolución de Tormenta Eléctrica Mediante Balón de Contrapulsación en Paciente Bajo Asistencia Circulatoria Mecánica Compleja

Year: 2015
Type: article
Study design: Case Report
Abstract: Reversal of Electrical storm after Intra-aortic Balloon Pump CounterpulsationBalloon pump counterpulsation has been used for stabilization of refractory ventricular arrhythmia both in coronary and non-coronary patients; its usefulness for complex circulatory support is still under consideration.We report a case of electrical storm reversal after intra-aortic balloon pump counterpulsation in a patient without coronary artery disease and under biventricular support with continuous-flow devices.Our case is a 44-year-old male patient with idiopathic dilated cardiomyopathy and severe impairment ventricular function (22%) determined by echocardiography; he was admitted to the intensive care unit due to progression of dyspnea in functional class II to IV with urine output deterioration.He presented a cardiac index (CI) of 1.2 L/min/m2 and 35 mm Hg of wedge pressure.He received diuretics and dobutamine at an initial intravenous dose of 5 µg/kg/min, increasing the dose to 15 µg/kg/min due to oliguria, acidosis, and persistent low CI.The patient developed complex ventricular arrhythmia (frequent ventricular extrasystoles, couplets and triplets, and several episodes of self-limiting ventricular tachycardia), which was treated successively with magnesium, lidocaine, and amiodarone.Due to the potential dobutamine proarrhythmic effect, milrinone therapy (0.5 µg/kg/min) was started in order to reduce the dobutamine dose.The following day, under dobutamine 2.5 µg/kg/ min and milrinone 0.75 µg/kg, the patient developed sustained ventricular tachycardia and required defibrillation, orotracheal intubation and mechanical ventilation, and underwent implantation of balloon pump counterpulsation with amiodarone load and maintenance.In the next 12 hours, under balloon support, the patient remained without complex forms of ventricular arrhythmia, but due to his progression to anuria with metabolic acidosis and CI of 1.2 L/min/m2 (under milrinone 0.75 µg/kg/min), percutaneous placement of a CentriMag continuous-flow left ventricular assist device (Levitronix LLC, Waltham, Mass) and balloon removal was decided.Subsequently, and given the severe right ventricular dysfunction resistant to pharmacological therapy, a second CentriMag right ventricular assist device was placed.Two hours after the intervention, the patient developed electrical storm that was refractory to lidocaine, amiodarone loading, pacing attempts -suppression -and multiple defibrillations; he persisted with ventricular tachycardia for 24 hours (Figure 1).In such circumstances, balloon pump counterpulsation was reimplanted to stop the arrhythmia, which was resolved 2 hours after the intervention.Four days after the procedure, under balloon and
Language: Spanish
Field: Medicine
Open Access status: green
OpenAlex ID: W2764556547
FWCI:
Cites: 10
Cited by:
Related to: 10