Passive Vibration Damping in a Truss Telecommunication Tower
Year: 2014
Type: article
Abstract: A dynamic model of a truss telecommunication tower was developed. A viscoelastic absorber was proposed for reducing structural vibrations caused by wind. Small linear system vibrations were assumed. A finite element three-dimensional model was used to determine the damper viscoelastic parameters which guarantee the highest damping effectiveness. Simulation results indicate that a damper can reduce the amplitude of tower vibrations by half and produce a similar reduction in forces acting upon the most loaded members of the structure.
Source: Technical Sciences
Authors: Józef Pelc, B. Kolator
Institution: University of Warmia and Mazury in Olsztyn
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond