Sp578patient Perceptions of a New Non-surgical Approach to Arteriovenous Fistula Creation and Use for Hemodialysis
Year: 2017
Type: conference-abstract
Abstract: INTRODUCTION AND AIMS: While the arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis, patients’ fears about surgery and complications often result in refusal or delay of AVF creation. A new endovascular method using magnetic catheters and radiofrequency energy to create an AVF (without open surgery) has recently been developed (everlinQ endoAVF). This endoAVF was recently studied in the Novel Endovascular Access Trial (NEAT). We report the results of the patient-reported satisfaction and perceptions on quality of life (QOL) factors (KDQOL-SF) associated with the endoAVF. METHODS: NEAT was a multicenter prospective single arm study conducted in Canada and Australia/New Zealand that reported on 60 evaluable patients (57% were predialysis). Participants were asked to complete two self-administered questionnaires, Vascular Access Questionnaire (VAQ) and the disease-specific KDQOL-SF, at baseline, 6 months and 12 months. We evaluated the results from participants who used their endoAVF for dialysis to determine how satisfied or bothered they were with vascular access-related issues that impact QOL. RESULTS: In NEAT, 67% (28/42) of 12-month evaluable patients successfully used their endoAVF (>2/3 of dialysis sessions over 4 weeks). 89% of these participants who used their endoAVF for hemodialysis completed the questionnaires. Results of the VAQ revealed that 96% of patients were satisfied with their endoAVF, 72% would recommend the endoAVF to a friend, 88% found it easy to use, and only 16% would change their access type if possible. Mean likert scores (0 = not at all bothered, 1= a little bothered, 4 = extremely bothered) for physical complications indicated patients were “not at all” or “a little” bothered with pain (1.1), bleeding (0.5), bruising (0.8), swelling (0.7), redness (0.4), infection (0.1), and clotting (0.6). Similarly, mean likert values indicated the endoAVF did “not at all” affect social functioning aspects for appearance (0.8), interference with daily activities (0.5), interference with social activities (0.7), problems sleeping with access (0.3), and protecting access (0.8). For perceptions of complications, patients indicated that they were “not at all” worried about endoAVF working on dialysis (0.6), problems with their access (0.9), having to come early (0.1) or leave late (0.5) because of access problems, and were only “a little” worried about endoAVF longevity (1.3). The KDQOL-SF revealed that burden of disease, symptoms, sleep, overall health and patient satisfaction all demonstrated an improvement after using the endoAVF (Figure 1.) SP578 Figure
DOI: 10.1093/ndt/gfx153
Authors: Charmaine Lok, On Behalf of NEAT Investigators
Institution: University Health Network
Language: English
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W2783148816
