Working fluid selection for a facade integrated solar cooling system
Year: 2014
Type: conference-paper
Abstract: A façade integrated solar power generation system has the potential to reduce fossil fuel energy use, and to make the building envelope better thermally perform.The façade integrated system proposed in this study consists of evacuated tube solar collectors (ETSC) installed in the cavity of double skin façades (DSF) to collect solar energy to be used in an organic Rankine cycle (ORC).A subcritical ORC with regenerator configuration is adopted.To maximise the overall system performance, the working fluid used in the ORC needs to be selected carefully.Various working fluids (R134a, R290, R227ea and R152a) were compared to be employed in the system.The selection is based on thermal efficiency, exergy efficiency, pressure ratio, volume flow rate at the expander of the Rankine cycle, as well as considering safety and environmental issues of working fluids.Engineering Equation Solver (EES) was used to evaluate the system performance by applying the first and second law of thermodynamics.R134a and R152a with superheating appear as most suitable working fluids for the ORC under the predefined operating conditions of the façade integrated system.
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green