Abstract: In order to be used for the development of a design model for local buckling of fire exposed aluminium sections, FE models are developed and validated with tests in this report.The validation is based on three types of tests: -Compression tests on thin walled square hollow sections (SHS) and angles at room temperature; -Steady-state compression tests on thin walled SHS and angles at elevated temperature, which are carried out in the same way as at room temperature, i.e. the specimen is brought to a constant, elevated temperature and subsequently loaded with a certain strain rate until collapse occurs; -Transient-state compression tests on thin walled SHS and angles, in which the load on the specimen remains constant and the temperature increases with an approximately constant heating rate, until collapse occurs.The average value of the ratios between the ultimate buckling resistance of the model and of the steady-state test (at room and elevated temperature) is 1,03 and 1,12 for square hollow sections (SHS) and angles, respectively.The standard deviation of these ratios is 0,08 and 0,12 for SHS and angles, respectively.(Total amount of tests: 19 and 9 for SHS and angles, respectively.) C Model with solid elements D Construction of stress-strain relationships for steady state compression testsError! Reference source not found.| Report no.
Source: TU/e Research Portal
Author: Johan Maljaars
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2802887927