Year: 2017
Type: conference-paper
Abstract: Higher power cathodes are increasingly utilizing LaB6 emitters due to their increased emission current density capabilities over barium oxide emitters, however, these emitters require higher operating temperatures which poses a significant challenge to maintain heater reliability. Hence, there is ongoing development of heaterless hollow cathodes that allow for potentially higher reliability through design simplicity of removing the heater component, and in addition, there is potential savings in mass, volume, ignition time and power. In this study a LaB6 heaterless hollow cathode with imbedded high temperature thermocouple instrumentation demonstrated reliably operation in diode mode from 5-8 A at xenon flow rates of 0.2-1.75 sccm. Thet emperature profile of the emitter is characterized through ignition, which lasts up to 50 seconds. In addition, pyrometer measurements in an open keeper configuration have shown the emitter surface temperature to be significantly lower than that predicted by the Richardson equation for LaB6 emitter, perhaps indicating a strong influence of the surface chemistry.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2803638815