Work

Structural Integrity Evaluation of Multiple Axial Through-wall Cracks in Steam Generator Tube

Year: 2001
Type: conference-paper
Abstract: It is commonly required that tubes with defects exceeding 40% of wall thickness in depth should be plugged but this criterion is considered to be too conservative for some locations and types of defects.Many studies have been done to develop alternative plugging criteria and have shown that a certain range of axial through-wall cracks in steam generator tubes could remain in service without any safety or reliability problems.But these approaches are limited, so far, to single cracked tubes whereas multiple cracks could be found more often than not.A crack coalescence model applicable to steam generator tubes with two collinear axial through-wall cracks was proposed in the previous study.In this paper, the investigation is extended to the parallel axial cracks spaced in circumferential direction because parallel axial cracks are more frequently detected during the in-service inspection than collinear axial cracks.Interaction effects between two parallel cracks are evaluated by performing elastic and elastic-plastic finite element analyses.
Language: English
Open Access status: green
OpenAlex ID: W2804664495
FWCI:
Cites: 7
Cited by: