Comparison of microdosimetry-based absorbed doses to control tumours and clinically obtained tumour absorbed doses in treatments with 223 Ra

Year: 2018
Type: article
Abstract: We performed Monte Carlo simulations in order to determine by means of microdosimetry calculations the average number of hits to the cell nucleus required to reach a tumour control probability (TCP) of 0.9, , for the source geometry of a nucleus embedded in a homogeneous distribution of 223 Ra atoms. From the results obtained and following the MIRD methodology, we determined the values of lesion absorbed doses needed to reach a TCP of 0.9, , for different values of mass density, cell radiosensitivity, nucleus radius and lesion volume. The greatest variation of those absorbed doses occurred with cell radiosensitivity and no dependence was found on mass density. The source geometry used was chosen because we aimed to compare the values of with the lesion absorbed doses obtained from image-based macrodosimetry in treatments of metastatic castration-resistant prostate cancer with 223 Ra which were obtained assuming a homogeneous distribution of 223 Ra atoms within the lesion. In a comparison with a study including 29 lesions, results showed that even for the case of the most radiosensitive cells simulated, 45% of the lesions treated following a schedule of two cycles of 110 kBq kg −1 body mass would receive absorbed doses below the values of determined in this study.
Language: English
Field: Medicine
Open Access status: bronze
OpenAlex ID: W2808719560
FWCI: 0.345
Cites: 33
Cited by: 7
Related to: 10