Evaluation of the use of zeolite mixtures in the submerged demineralizer system (SDS) flowsheet for decontamination of high-activity-level water at the Three Mile Island Nuclear Power Station, Unit 2

Year: 1983
Type: article
Abstract: Mixtures of Linde Ionsiv IE-96 and Linde Ionsiv A-51 were evaluated for use in the Submerged Demineralizer System (SDS) that was installed at the Three Mile Island Nuclear Power Station, Unit 2 (TMI-2) for decontaminating approx. 2650 m/sup 3/ of high-activity-level water (HALW) in the Containment Building (CB) sump.