Performance of Filtering Facepieces and Powered Air-purifying Respirators Challenged with Different Aerosols
Year: 2016
Type: article
Abstract: The main objective of this research was to evaluate the performance of various respiratory protective devices (RPDs) against different aerosols.The tested devices included surgical masks, N95, R95, P95 and N100 filtering facepiece respirators (FFRs), and powered airpurifying respirators (PAPRs).Challenge aerosols included sodium chloride (NaCl) particles, combustion particles generated by burning of wood, paper and plastic materials, and surgical smoke generated by cutting the animal tissue.Sodium chloride particles were used as the "model" challenge aerosols, and the RPD performance data collected were compared to those obtained with real workplace aerosols.The effects of multiple factors such as challenge aerosol type, breathing flow rates including constant inhalation flow and cyclic flow, particle size, relative humidity of the ambient air, and respirator type on the RPDs' performance were evaluated. This dissertation describes four related studies (A-D).In study A (Chapter 1), the filter samples of N95, R95 and P95 FFRs were challenged against NaCl particles and combustion particles generated by burning of wood, paper and plastic materials.The study revealed that the penetration of combustion particles was significantly higher than that of NaCl particles.However, this result was not observed for R95 and P95 FFR filters.Challenge aerosol type, constant inhalation flow rate, and particle size were significant factors on the filter performance of N95 FFR.V Results and Discussion .......
Author: Shuang Gao
Institution: University of Cincinnati
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
Awards: G1964935750, G5496779201
OpenAlex ID: W2883209340