Stator Turn Fault Modeling for a Triple Redundant 3 × 3-Phase PMA SynRM

Year: 2018
Type: article
Abstract: Accurate stator turn fault (STF) modeling technique is of paramount importance to assess the machine fault behavior and develop fault detection and mitigation strategies for a fault-tolerant machine drive system. In this paper, an STF model is proposed for a triple redundant 3 × 3-phase permanent-magnet-assisted synchronous reluctance machine. The effect of turn fault current is represented by equivalent inputs to a general flux linkage model for each three-phase set. Subsequently, the flux linkage of the fault turns is derived according to the coil location and slot position of the fault. The complete model is obtained by combining the flux linkage model with the governing voltage equations. The effectiveness and flexibility of the proposed model have been validated by extensive finite element simulations and experimental tests in various operation conditions. It is demonstrated that the model can predict the machine behavior with and without the mitigation action in the form of terminal short circuit.
Language: English
Open Access status: green
OpenAlex ID: W2911511630
FWCI: 0.18
Cites: 26
Cited by: 10