Year: 2018
Type: article
Abstract: Accurate stator turn fault (STF) modeling technique is of paramount importance to assess the machine fault behavior and develop fault detection and mitigation strategies for a fault-tolerant machine drive system. In this paper, an STF model is proposed for a triple redundant 3 × 3-phase permanent-magnet-assisted synchronous reluctance machine. The effect of turn fault current is represented by equivalent inputs to a general flux linkage model for each three-phase set. Subsequently, the flux linkage of the fault turns is derived according to the coil location and slot position of the fault. The complete model is obtained by combining the flux linkage model with the governing voltage equations. The effectiveness and flexibility of the proposed model have been validated by extensive finite element simulations and experimental tests in various operation conditions. It is demonstrated that the model can predict the machine behavior with and without the mitigation action in the form of terminal short circuit.
Authors: Bo Wang, Jiabin Wang, Antonio Griffo
Institutions: Southeast University, University of Sheffield
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2911511630